Sterilization & Quality

Our Commitment to
Clinical Safety

Every instrument, every surface, every cycle — tracked, tested, and logged. This live dashboard reflects the real-time status of our sterilization and infection control systems.

Live Status

Quality at a Glance

Updated weekly by our sterilization officer. All indicators are reviewed and signed off by our head clinician.

Last Autoclave BI Test
7 April 2026
PASS — Negative Growth
Waterline Maintenance
4 April 2026
PASS — Within <500 CFU/mL
Autoclave Cycle Temp
134 °C — 18 min
CLASS B CYCLE
Air Purification System
HEPA-14 Active
OPERATIONAL
Weekly Autoclave BI Test Log Last updated: 7 Apr 2026
Date Autoclave Unit Cycle Temp / Time BI Result Verified By
7 Apr 2026 SciCan STATIM 5000 Class B 134°C / 18 min PASS Sr. Nurse Amara
31 Mar 2026 SciCan STATIM 5000 Class B 134°C / 18 min PASS Dr. Kanya
24 Mar 2026 W&H Lisa Class B 134°C / 18 min PASS Sr. Nurse Amara
17 Mar 2026 SciCan STATIM 5000 Class B 134°C / 18 min PASS Sr. Nurse Amara
10 Mar 2026 W&H Lisa Class B 134°C / 18 min PASS Dr. Kanya
3 Mar 2026 SciCan STATIM 5000 Class B 134°C / 18 min PASS Sr. Nurse Amara
24 Feb 2026 W&H Lisa Class B 134°C / 18 min PASS Sr. Nurse Amara
17 Feb 2026 SciCan STATIM 5000 Class B 134°C / 18 min PASS Dr. Kanya
Waterline Maintenance Log Last updated: 4 Apr 2026
Date Unit / Chair CFU/mL Status
4 Apr 2026 Chair 1 Handpiece < 50 PASS
4 Apr 2026 Chair 2 Handpiece < 50 PASS
4 Apr 2026 Chair 3 Handpiece < 80 PASS
4 Apr 2026 Surgical Suite < 30 PASS
7 Mar 2026 Chair 1 Handpiece < 50 PASS
7 Mar 2026 Chair 2 Handpiece < 70 PASS
7 Mar 2026 Surgical Suite < 30 PASS
Read-Only Registry

Equipment Serials & Warranty

All clinical sterilization equipment is registered, under active warranty, and seiced on schedule.

Autoclaves & Sterilizers
SciCan STATIM 5000
Class B Steam Autoclave — Cassette Type S/N: SC5K-2022-TH-00412 Warranty valid until Dec 2027
W&H Lisa
Class B Benchtop Autoclave — 17 L S/N: WH-LISA-TH-20230078 Warranty valid until Mar 2028
Melag Vacuklav 44B+
Class B Vacuum Autoclave — 22 L S/N: MEL-44B-TH-00891 Warranty valid until Jun 2026
Air & Surface Hygiene
IQAir GC MultiGas
HEPA-14 Air Purifier — Surgical Grade S/N: IQ-GCMG-TH-20240115 Warranty valid until Jan 2029
Dürr Dental AC 300
Amalgam & Aerosol Separator S/N: DD-AC300-TH-00234 Warranty valid until Aug 2027
Ultrasonic Cleaner
Bandelin Sonorex Digitec — Pre-sterilization S/N: BD-SNRX-TH-20220544 Warranty valid until Nov 2026
Chemical Disinfection Systems
Dürr Dental FD 366
Surface Disinfectant Spray System — EN 14476 Certified Batch: FD366-2026-Q1 Expiry: Dec 2026
Cidex OPA
High-Level Disinfectant for Semi-Critical Instruments Batch: CIDEX-OPA-2026-B4 Expiry: Jul 2026
Monitoring & Testing
Mesa Labs Biological Indicators
Geobacillus stearothermophilus — Weekly BI Testing Lot: MESA-BI-2026-04 Expiry: Sep 2026
Sterrad NX Cycle Indicators
Class 5 Chemical Integrators — per-pack monitoring Lot: STD-CLASS5-2026-Q1 Expiry: Dec 2026
Our Instrument Sterilization Protocol — Every Single Time
Step 01
Pre-Rinse & Scrub
Instruments are rinsed of gross debris immediately after use.
Step 02
Ultrasonic Bath
15-minute ultrasonic cycle removes biofilm and contaminants.
Step 03
Pouching
Each instrument is individually sealed in a sterilization pouch with a Class 5 indicator strip.
Step 04
Autoclave Cycle
134°C Class B steam cycle for 18 minutes. Logged digitally.
Step 05
Verification
Indicator checked. BI test performed weekly. Records filed monthly.